Use CasesStable transfer of sample solution for observation of atom movement
Liquid Type | |
---|---|
Process Type | |
Industry | |
Problem |
Customer
High Energy Accelerator Research Organization
Customer's Needs and Problems
An organic solvent containing a photocatalyst is circulated through the system with a pump and is sprayed from a jet nozzle. This spray is irradiated with an ultraviolet laser beam for excitation and an X-ray laser beam for observation, and the movement of the atoms due to photochemical reactions is observed (the X-ray temporal resolution is measured).
Conventionally, a magnetic drive gear pump, a diaphragm pump, or a similar pump was used. The use of such a pump posed the following problems.
TACMINA's Solutions
The customer decided to use a Q Series Smoothflow Pump.
Product
- Q
- Max. discharge volume
- 0.005~100mL/min
- Max. discharge pressure
- 3.0MPa
Compatible with acids, bases and solvents. Precise Liquid Supplying with Trace Amounts in Laboratory Processes!
- Direct-Driven Type
- Precision
- Trace Amount Supply