Use CasesAccurate management of residual chlorine concentration in the rinsing water for wash bottles
Liquid Type | |
---|---|
Process Type | |
Industry | |
Problem |
Customer
Beverage manufacturer
Customer's Needs and Problems
Sample water is supplied to a residual chlorine meter in order to measure the chlorine concentration in the rinsing water used for wash bottles.
Currently, instead of a pump, bypass piping is used, which poses the following problems.
TACMINA's Solutions
We suggested that the customer use a Smoothflow Pump for sampling, and they agreed to this proposal.
A new sampling tank was installed, and the sampling line and wash bottle line were separated.
Flow Diagram
Product
- PL (Direct-Driven Type)
- Max. discharge volume
- 0.24~28L/min
- Max. discharge pressure
- 1.0MPa
Ideal for metered supply/injection of a wide range of chemicals and fluids, for example, long-distance transfer of water treatment chemicals and injection of additives
- Direct-Driven Type
- Trace Amount Injection