Solenoid-Driven Metering PumpsWhat Is a Solenoid-Driven Metering Pump?

A Solenoid-Driven Metering Pump is suitable when a wider control band of discharge volume is required or when complex control using external signals is required. The Solenoid-Driven Metering Pump has a maximum of 300 strokes/min (TACMINA benchmark), which means that it is 2 to 4 times faster than Motor-Driven Metering Pumps, and is capable of operation at a rate of once per minute (a control band of 300:1). It has an embedded controller and can be programmed to operate in a variety of ways..

[Small Capacity] S-size only S-size only / PZ Manual Setting / PZ No-input, [Small Capacity] Standard High-viscosity Boler / PW Digital Setting Multi Functions / PW Digital-input/output PWM Digital-input/output & Analog-input PWT Digital-input/output & Timer Control, [Middle Capacity] PZD PZi / PZD Digital Setting PZD No-input PZi Digital Setting Advanced Functions / PZi4 Digital-input & Analog-input PZi8 Digital-input/Output & Analog-Output, [Large Capacity] Standard High-viscosity type / PZiG Digital Setting Advanced Functions PZiG / Digital-input/output & Analog-input, [For Sodium Hypochlorite] DCLPW CLPW CLPZ / DCLPW Air Block In-Line Automatic Air-release CLPW In-Line Automatic Air-release / DCLPW Digital-input/output DCLPWM Digital-input/output & Analog-input DCLPWT Digital-input/output & Timer Control CLPW Digital-input/output CLPWM Digital-input/output & Analog-input CLPWT Digital-input/output & Timer Control

Choose by Application

For Injection of Generic Chemicals

Small Capacity PZ Manual Setting w/ Relief Value 30R Max. discharge volume (mL/min) 30 Max. discharge volume (L/h) 1.8 Max. discharge pressure (MPa) 0.7 Max. discharge pressure (bar) 7.0 Small Capacity PZ Manual Setting w/ Relief Value 60R Max. discharge volume (mL/min) 60 Max. discharge volume (L/h) 3.6 Max. discharge pressure (MPa) 0.7 Max. discharge pressure (bar) 7.0 Small Capacity PZ Manual Setting w/ Relief Value 100R Max. discharge volume (mL/min) 100 Max. discharge volume (L/h) 6.0 Max. discharge pressure (MPa) 0.4 Max. discharge pressure (bar) 4.0 Small Capacity PZ Manual Setting 30 Max. discharge volume (mL/min) 30 Max. discharge volume (L/h) 1.8 Max. discharge pressure (MPa) 1.0 Max. discharge pressure (bar) 10.0 Small Capacity PZ Manual Setting 60 Max. discharge volume (mL/min) 60 Max. discharge volume (L/h) 3.6 Max. discharge pressure (MPa) 0.8 Max. discharge pressure (bar) 8.0 Small Capacity PZ Manual Setting 100 Max. discharge volume (mL/min) 100 Max. discharge volume (L/h) 6.0 Max. discharge pressure (MPa) 0.4 Max. discharge pressure (bar) 4.0 Small Capacity PW Digital Setting Multi Functions PW PWM PWT w/ Relief Value 30R Max. discharge volume (mL/min) 30 Max. discharge volume (L/h) 1.8 Max. discharge pressure (MPa) 0.7 Max. discharge pressure (bar) 7.0 Small Capacity PW Digital Setting Multi Functions PW PWM PWT w/ Relief Value 60R Max. discharge volume (mL/min) 60 Max. discharge volume (L/h) 3.6 Max. discharge pressure (MPa) 0.7 Max. discharge pressure (bar) 7.0 Small Capacity PW Digital Setting Multi Functions PW PWM PWT w/ Relief Value 100R Max. discharge volume (mL/min) 100 Max. discharge volume (L/h) 6.0 Max. discharge pressure (MPa) 0.7 Max. discharge pressure (bar) 7.0 Small Capacity PW Digital Setting Multi Functions PW PWM PWT 30 Max. discharge volume (mL/min) 30 Max. discharge volume (L/h) 1.8 Max. discharge pressure (MPa) 1.0 Max. discharge pressure (bar) 10.0 Small Capacity PW Digital Setting Multi Functions PW PWM PWT 60 Max. discharge volume (mL/min) 60 Max. discharge volume (L/h) 3.6 Max. discharge pressure (MPa) 1.0 Max. discharge pressure (bar) 10.0 Small Capacity PW Digital Setting Multi Functions PW PWM PWT 100 Max. discharge volume (mL/min) 100 Max. discharge volume (L/h) 6.0 Max. discharge pressure (MPa) 0.7 Max. discharge pressure (bar) 7.0 Small Capacity PW Digital Setting Multi Functions PW PWM PWT 200 Max. discharge volume (mL/min) 220 Max. discharge volume (L/h) 13.2 Max. discharge pressure (MPa) 0.2 Max. discharge pressure (bar) 2.0 Middle Capacity PZD Digital Setting 300 Max. discharge volume (mL/min) 360 Max. discharge volume (L/h) 21.6 Max. discharge pressure (MPa) 0.3 Max. discharge pressure (bar) 3.0 Middle Capacity PZD Digital Setting 500 Max. discharge volume (mL/min) 540 Max. discharge volume (L/h) 32.4 Max. discharge pressure (MPa) 0.2 Max. discharge pressure (bar) 2.0 Middle Capacity PZi PZi4 PZi8 Digital Setting Advanced Functions 300 Max. discharge volume (mL/min) 360 Max. discharge volume (L/h) 21.6 Max. discharge pressure (MPa) 0.3 Max. discharge pressure (bar) 3.0 Middle Capacity PZi PZi4 PZi8 Digital Setting Advanced Functions 500 Max. discharge volume (mL/min) 540 Max. discharge volume (L/h) 32.4 Max. discharge pressure (MPa) 0.2 Max. discharge pressure (bar) 2.0 Large Capacity PZiG Digital Setting PZiG Advanced Functions 300 Max. discharge volume (mL/min) 340 Max. discharge volume (L/h) 20.4 Max. discharge pressure (MPa) 1.0 Max. discharge pressure (bar) 10.0 Large Capacity PZiG Digital Setting PZiG Advanced Functions 500 Max. discharge volume (mL/min) 530 Max. discharge volume (L/h) 31.8 Max. discharge pressure (MPa) 0.7 Max. discharge pressure (bar) 7.0 Large Capacity PZiG Digital Setting PZiG Advanced Functions 700 Max. discharge volume (mL/min) 760 Max. discharge volume (L/h) 45.6 Max. discharge pressure (MPa) 0.4 Max. discharge pressure (bar) 4.0 Large Capacity PZiG Digital Setting PZiG Advanced Functions 1000 Max. discharge volume (mL/min) 1000 Max. discharge volume (L/h) 60.0 Max. discharge pressure (MPa) 0.3 Max. discharge pressure (bar) 3.0

For Injection of High Viscosity Medicines

Small Capacity PZ Manual Setting w/ Relief Value 30R Max. discharge volume (mL/min) 28 Max. discharge volume (L/h) 1.68 Max. discharge pressure (MPa) 1.5 Max. discharge pressure (bar) 15.0 Small Capacity PZ Manual Setting 30 Max. discharge volume (mL/min) 28 Max. discharge volume (L/h) 1.68 Max. discharge pressure (MPa) 1.5 Max. discharge pressure (bar) 15.0 Small Capacity PW Digital Setting Multi Functions PW PWM PWT w/ Relief Value 30R Max. discharge volume (mL/min) 28 Max. discharge volume (L/h) 1.68 Max. discharge pressure (MPa) 1.5 Max. discharge pressure (bar) 15.0 Small Capacity PW Digital Setting Multi Functions PW PWM PWT 30 Max. discharge volume (mL/min) 28 Max. discharge volume (L/h) 1.68 Max. discharge pressure (MPa) 1.5 Max. discharge pressure (bar) 15.0 Small Capacity PW Digital Setting Multi Functions PW PWM PWT 30 Max. discharge volume (mL/min) 25 Max. discharge volume (L/h) 1.5 Max. discharge pressure (MPa) 2.0 Max. discharge pressure (bar) 20.0

For Injection of Boiler Chemicals/High-Pressure

Small Capacity PW Digital Setting Multi Functions PW PWM PWT 60 Max. discharge volume (mL/min) 60 Max. discharge volume (L/h) 3.6 Max. discharge pressure (MPa) 1.0 Max. discharge pressure (bar) 10.0 Small Capacity PW Digital Setting Multi Functions PW PWM PWT 100 Max. discharge volume (mL/min) 100 Max. discharge volume (L/h) 6.0 Max. discharge pressure (MPa) 0.7 Max. discharge pressure (bar) 7.0 Middle Capacity PZD Digital Setting PZD 300 Max. discharge volume (mL/min) 360 Max. discharge volume (L/h) 21.6 Max. discharge pressure (MPa) 0.3 Max. discharge pressure (bar) 3.0 Middle Capacity PZD Digital Setting PZD 500 Max. discharge volume (mL/min) 540 Max. discharge volume (L/h) 32.4 Max. discharge pressure (MPa) 0.2 Max. discharge pressure (bar) 2.0 Large Capacity PZiG Digital Setting Advanced Functions PZiG 300 Max. discharge volume (mL/min) 340 Max. discharge volume (L/h) 20.4 Max. discharge pressure (MPa) 1.0 Max. discharge pressure (bar) 10.0 Large Capacity PZiG Digital Setting Advanced Functions PZiG 500 Max. discharge volume (mL/min) 530 Max. discharge volume (L/h) 31.8 Max. discharge pressure (MPa) 0.7 Max. discharge pressure (bar) 7.0 Large Capacity PZiG Digital Setting Advanced Functions PZiG 700 Max. discharge volume (mL/min) 760 Max. discharge volume (L/h) 45.6 Max. discharge pressure (MPa) 0.4 Max. discharge pressure (bar) 4.0 Large Capacity PZiG Digital Setting Advanced Functions PZiG 1000 Max. discharge volume (mL/min) 1000 Max. discharge volume (L/h) 60.0 Max. discharge pressure (MPa) 0.3 Max. discharge pressure (bar) 3.0

For Injection of Sodium Hypochlorite (NaClO)

DCLPW Air Block In-Line Automatic Air-release DCLPW DCLPWM DCLPWT 30R w/ Relief Value Max. discharge volume (mL/min) 30 Max. discharge volume (L/h) 1.8 Max. discharge pressure (MPa) 0.7 Max. discharge pressure (bar) 7.0 DCLPW Air Block In-Line Automatic Air-release DCLPW DCLPWM DCLPWT 60R w/ Relief Value Max. discharge volume (mL/min) 60 Max. discharge volume (L/h) 3.6 Max. discharge pressure (MPa) 0.7 Max. discharge pressure (bar) 7.0 DCLPW Air Block In-Line Automatic Air-release DCLPW DCLPWM DCLPWT 100R w/ Relief Value Max. discharge volume (mL/min) 90 Max. discharge volume (L/h) 5.4 Max. discharge pressure (MPa) 0.7 Max. discharge pressure (bar) 7.0 DCLPW Air Block In-Line Automatic Air-release DCLPW DCLPWM DCLPWT 30 Max. discharge volume (mL/min) 30 Max. discharge volume (L/h) 1.8 Max. discharge pressure (MPa) 1.0 Max. discharge pressure (bar) 10.0 DCLPW Air Block In-Line Automatic Air-release DCLPW DCLPWM DCLPWT 60 Max. discharge volume (mL/min) 60 Max. discharge volume (L/h) 3.6 Max. discharge pressure (MPa) 1.0 Max. discharge pressure (bar) 10.0 DCLPW Air Block In-Line Automatic Air-release DCLPW DCLPWM DCLPWT 100 Max. discharge volume (mL/min) 90 Max. discharge volume (L/h) 5.4 Max. discharge pressure (MPa) 0.7 Max. discharge pressure (bar) 7.0 CLPW In-Line Automatic Air-release CLPW CLPWM CLPWT 30R w/ Relief Value Max. discharge volume (mL/min) 30 Max. discharge volume (L/h) 1.8 Max. discharge pressure (MPa) 0.7 Max. discharge pressure (bar) 7.0 CLPW In-Line Automatic Air-release CLPW CLPWM CLPWT 60R w/ Relief Value Max. discharge volume (mL/min) 60 Max. discharge volume (L/h) 3.6 Max. discharge pressure (MPa) 0.7 Max. discharge pressure (bar) 7.0 CLPW In-Line Automatic Air-release CLPW CLPWM CLPWT 100R w/ Relief Value Max. discharge volume (mL/min) 90 Max. discharge volume (L/h) 5.4 Max. discharge pressure (MPa) 0.7 Max. discharge pressure (bar) 7.0 CLPW In-Line Automatic Air-release CLPW CLPWM CLPWT 30 Max. discharge volume (mL/min) 30 Max. discharge volume (L/h) 1.8 Max. discharge pressure (MPa) 1.0 Max. discharge pressure (bar) 10.0 CLPW In-Line Automatic Air-release CLPW CLPWM CLPWT 60 Max. discharge volume (mL/min) 60 Max. discharge volume (L/h) 3.6 Max. discharge pressure (MPa) 1.0 Max. discharge pressure (bar) 10.0 CLPW In-Line Automatic Air-release CLPW CLPWM CLPWT 100 Max. discharge volume (mL/min) 90 Max. discharge volume (L/h) 5.4 Max. discharge pressure (MPa) 0.7 Max. discharge pressure (bar) 7.0

Choose by Function

Small Capacity PZ Signal(No. of ports) Digital Input ― Signal(No. of ports) Digital Output ― Signal(No. of ports) Analog Input ― Power supply to Flow Checker ― Control Manual Stroke speed ○ Control Manual Discharge volume ― Control Manual Percentage ― Control Auto Pulse-input proportional control ○ Control Auto Analog-input proportional control ― Control Auto Interval operation ― Control Auto Timer control ― Control Auto Count operation (batch control) ― Control Auto External operation-signal control ― Control Auto External stop-signal control ― Control Auto 2-point Level Switch control*1 ― Control ECO mode ― Control SAFE mode ― Control Relief valve function ― Control Alarm function ― Error/Alarm Memory-read error (LCD display only) ― Error/Alarm Tank-level alarm w/1-point Level Switch ― Error/Alarm Tank-level alarm w/2-point Level Switch ― Error/Alarm Pulse-Input error ― Error/Alarm Analog-Input error ― Error/Alarm Lower discharge-volume alarm*2 ― Easy calibration function ― Momentary discharge-volume display function*2 ― Small Capacity PW Signal(No. of ports) Digital Input 2 Signal(No. of ports) Digital Output 2 Signal(No. of ports) Analog Input ― Power supply to Flow Checker ― Control Manual Stroke speed ○ Control Manual Discharge volume ○ Control Manual Percentage ― Control Auto Pulse-input proportional control ○ Control Auto Analog-input proportional control ― Control Auto Interval operation ― Control Auto Timer control ― Control Auto Count operation (batch control) ― Control Auto External operation-signal control ○ Control Auto External stop-signal control ○ Control Auto 2-point Level Switch control*1 ○ Control ECO mode ○ Control SAFE mode ○ Control Relief valve function ○ Control Alarm function ○ Error/Alarm Memory-read error (LCD display only) ― Error/Alarm Tank-level alarm w/1-point Level Switch ○ Error/Alarm Tank-level alarm w/2-point Level Switch ― Error/Alarm Pulse-Input error ○ Error/Alarm Analog-Input error ○ Error/Alarm Lower discharge-volume alarm*2 ― Easy calibration function ○ Momentary discharge-volume display function*2 ― Small Capacity PWM Signal(No. of ports) Digital Input 1 Signal(No. of ports) Digital Output 2 Signal(No. of ports) Analog Input 1 Power supply to Flow Checker ― Control Manual Stroke speed ○ Control Manual Discharge volume ― Control Manual Percentage ― Control Auto Pulse-input proportional control ― Control Auto Analog-input proportional control ○ Control Auto Interval operation ― Control Auto Timer control ― Control Auto Count operation (batch control) ― Control Auto External operation-signal control ○ Control Auto External stop-signal control ○ Control Auto 2-point Level Switch control*1 ○ Control ECO mode ○ Control SAFE mode ○ Control Relief valve function ○ Control Alarm function ○ Error/Alarm Memory-read error (LCD display only) ― Error/Alarm Tank-level alarm w/1-point Level Switch ○ Error/Alarm Tank-level alarm w/2-point Level Switch ― Error/Alarm Pulse-Input error ○ Error/Alarm Analog-Input error ○ Error/Alarm Lower discharge-volume alarm*2 ― Easy calibration function ― Momentary discharge-volume display function*2 ― Small Capacity PWT Signal(No. of ports) Digital Input 2 Signal(No. of ports) Digital Output 2 Signal(No. of ports) Analog Input ― Power supply to Flow Checker ― Control Manual Stroke speed ○ Control Manual Discharge volume ― Control Manual Percentage ― Control Auto Pulse-input proportional control ○ Control Auto Analog-input proportional control ― Control Auto Interval operation ○ Control Auto Timer control ○ Control Auto Count operation (batch control) ― Control Auto External operation-signal control ○ Control Auto External stop-signal control ○ Control Auto 2-point Level Switch control*1 ○ Control ECO mode ○ Control SAFE mode ○ Control Relief valve function ○ Control Alarm function ○ Error/Alarm Memory-read error (LCD display only) ― Error/Alarm Tank-level alarm w/1-point Level Switch ○ Error/Alarm Tank-level alarm w/2-point Level Switch ― Error/Alarm Pulse-Input error ○ Error/Alarm Analog-Input error ○ Error/Alarm Lower discharge-volume alarm*2 ― Easy calibration function ― Momentary discharge-volume display function*2 ― Middle Capacity PZD Signal(No. of ports) Digital Input ― Signal(No. of ports) Digital Output ― Signal(No. of ports) Analog Input ― Power supply to Flow Checker ― Control Manual Stroke speed ○ Control Manual Discharge volume ○ Control Manual Percentage ○ Control Auto Pulse-input proportional control ― Control Auto Analog-input proportional control ― Control Auto Interval operation ― Control Auto Timer control ― Control Auto Count operation (batch control) ― Control Auto External operation-signal control ― Control Auto External stop-signal control ― Control Auto 2-point Level Switch control*1 ― Control ECO mode ― Control SAFE mode ― Control Relief valve function ― Control Alarm function ― Error/Alarm Memory-read error (LCD display only) ○ Error/Alarm Tank-level alarm w/1-point Level Switch ― Error/Alarm Tank-level alarm w/2-point Level Switch ― Error/Alarm Pulse-Input error ― Error/Alarm Analog-Input error ― Error/Alarm Lower discharge-volume alarm*2 ― Easy calibration function ○ Momentary discharge-volume display function*2 ― Middle Capacity PZi4 Signal(No. of ports) Digital Input 2 Signal(No. of ports) Digital Output ― Signal(No. of ports) Analog Input 1 Power supply to Flow Checker ― Control Manual Stroke speed ○ Control Manual Discharge volume ○ Control Manual Percentage ○ Control Auto Pulse-input proportional control ○ Control Auto Analog-input proportional control ○ Control Auto Interval operation ― Control Auto Timer control ― Control Auto Count operation (batch control) ― Control Auto External operation-signal control ― Control Auto External stop-signal control ○ Control Auto 2-point Level Switch control*1 ○ Control ECO mode ― Control SAFE mode ― Control Relief valve function ― Control Alarm function ― Error/Alarm Memory-read error (LCD display only) ○ Error/Alarm Tank-level alarm w/1-point Level Switch ○ Error/Alarm Tank-level alarm w/2-point Level Switch ― Error/Alarm Pulse-Input error ○(display only) Error/Alarm Analog-Input error ○(display only) Error/Alarm Lower discharge-volume alarm*2 ○(display only) Easy calibration function ― Momentary discharge-volume display function*2 ― Middle Capacity PZi8 Signal(No. of ports) Digital Input 4 Signal(No. of ports) Digital Output 2 Signal(No. of ports) Analog Input 1 Power supply to Flow Checker ○ Control Manual Stroke speed ○ Control Manual Discharge volume ○ Control Manual Percentage ○ Control Auto Pulse-input proportional control ○ Control Auto Analog-input proportional control ○ Control Auto Interval operation ○ Control Auto Timer control ― Control Auto Count operation (batch control) ○ Control Auto External operation-signal control ― Control Auto External stop-signal control ○ Control Auto 2-point Level Switch control*1 ○ Control ECO mode ― Control SAFE mode ― Control Relief valve function ― Control Alarm function ○ Error/Alarm Memory-read error (LCD display only) ○ Error/Alarm Tank-level alarm w/1-point Level Switch ○ Error/Alarm Tank-level alarm w/2-point Level Switch ○ Error/Alarm Pulse-Input error ○ Error/Alarm Analog-Input error ○ Error/Alarm Lower discharge-volume alarm*2 ○ Easy calibration function ― Momentary discharge-volume display function*2 ○ Large Capacity PZiG Signal(No. of ports) Digital Input 4 Signal(No. of ports) Digital Output 2 Signal(No. of ports) Analog Input 1 Power supply to Flow Checker ― Control Manual Stroke speed ○ Control Manual Discharge volume ○ Control Manual Percentage ○ Control Auto Pulse-input proportional control ○ Control Auto Analog-input proportional control ○ Control Auto Interval operation ○ Control Auto Timer control ― Control Auto Count operation (batch control) ○ Control Auto External operation-signal control ― Control Auto External stop-signal control ○ Control Auto 2-point Level Switch control*1 ○ Control ECO mode ― Control SAFE mode ― Control Relief valve function ― Control Alarm function ○ Error/Alarm Memory-read error (LCD display only) ○ Error/Alarm Tank-level alarm w/1-point Level Switch ○ Error/Alarm Tank-level alarm w/2-point Level Switch ○ Error/Alarm Pulse-Input error ○ Error/Alarm Analog-Input error ○ Error/Alarm Lower discharge-volume alarm*2 ― Easy calibration function ○ Momentary discharge-volume display function*2 ― For Sodium Hypochlorite DCLPW CLPW Signal(No. of ports) Digital Input 2 Signal(No. of ports) Digital Output 2 Signal(No. of ports) Analog Input ― Power supply to Flow Checker ― Control Manual Stroke speed ○ Control Manual Discharge volume ○ Control Manual Percentage ― Control Auto Pulse-input proportional control ○ Control Auto Analog-input proportional control ― Control Auto Interval operation ― Control Auto Timer control ― Control Auto Count operation (batch control) ― Control Auto External operation-signal control ○ Control Auto External stop-signal control ○ Control Auto 2-point Level Switch control*1 ○ Control ECO mode ― Control SAFE mode ○ Control Relief valve function ○ Control Alarm function ○ Error/Alarm Memory-read error (LCD display only) ― Error/Alarm Tank-level alarm w/1-point Level Switch ○ Error/Alarm Tank-level alarm w/2-point Level Switch ― Error/Alarm Pulse-Input error ○ Error/Alarm Analog-Input error ○ Error/Alarm Lower discharge-volume alarm*2 ― Easy calibration function ○ Momentary discharge-volume display function*2 ― For Sodium Hypochlorite DCLPWM CLPWM Signal(No. of ports) Digital Input 1 Signal(No. of ports) Digital Output 2 Signal(No. of ports) Analog Input 1 Power supply to Flow Checker ― Control Manual Stroke speed ○ Control Manual Discharge volume ― Control Manual Percentage ― Control Auto Pulse-input proportional control ― Control Auto Analog-input proportional control ○ Control Auto Interval operation ― Control Auto Timer control ― Control Auto Count operation (batch control) ― Control Auto External operation-signal control ○ Control Auto External stop-signal control ○ Control Auto 2-point Level Switch control*1 ○ Control ECO mode ― Control SAFE mode ○ Control Relief valve function ○ Control Alarm function ○ Error/Alarm Memory-read error (LCD display only) ― Error/Alarm Tank-level alarm w/1-point Level Switch ○ Error/Alarm Tank-level alarm w/2-point Level Switch ― Error/Alarm Pulse-Input error ○ Error/Alarm Analog-Input error ○ Error/Alarm Lower discharge-volume alarm*2 ― Easy calibration function ― Momentary discharge-volume display function*2 ― For Sodium Hypochlorite DCLPWT CLPWT Signal(No. of ports) Digital Input 2 Signal(No. of ports) Digital Output 2 Signal(No. of ports) Analog Input ― Power supply to Flow Checker ― Control Manual Stroke speed ○ Control Manual Discharge volume ― Control Manual Percentage ― Control Auto Pulse-input proportional control ○ Control Auto Analog-input proportional control ― Control Auto Interval operation ○ Control Auto Timer control ○ Control Auto Count operation (batch control) ― Control Auto External operation-signal control ○ Control Auto External stop-signal control ○ Control Auto 2-point Level Switch control*1 ○ Control ECO mode ― Control SAFE mode ○ Control Relief valve function ○ Control Alarm function ○ Error/Alarm Memory-read error (LCD display only) ― Error/Alarm Tank-level alarm w/1-point Level Switch ○ Error/Alarm Tank-level alarm w/2-point Level Switch ― Error/Alarm Pulse-Input error ○ Error/Alarm Analog-Input error ○ Error/Alarm Lower discharge-volume alarm*2 ― Easy calibration function ― Momentary discharge-volume display function*2 ― *1 When 2-point Level Switch is used *2 When Flow Checker is used