- Hydraulic mechanism that supports high-pressure injection.
- Relief mechanism for preventing pump failures and accidents caused by excessive pressure.
- Specifications can be flexibly changed to suit
liquid types and applications, such as the attachment
of heat insulation and cooling jackets, and the
separation of liquid end part.
- Sterilization-in-place (SIP) and cleaning-in-place (CIP) compatible (sanitary type only)
|
| Specification/Model |
PLS(M) |
PLZ(M) |
PLR(M) |
| -014 |
-020 |
-030 |
-028 |
-040 |
-056 |
-028 |
-040 |
-056 |
-080 |
-100 |
| Max. discharge volume(L/min) |
0.2 |
0.5 |
1.2 |
1.6 |
3.3 |
6.4 |
1.95 |
4.0 |
7.9 |
16.0 |
24.8 |
| Max. discharge pressure(MPa) |
2.5 |
1.5 |
2.5 |
1.7 |
2.5 |
1.2 |
0.7 |
0.6 |
| Transferrable viscosity (mPa•s) |
50 mPa•s or less |
| Transferrable temperature (ºC) |
SUS:0 to 80ºC / PVC:0 to 40ºC (no
freezing allowed) |
| Connection type |
Hose, flange, union, ferrule, or special
type |
| Motor |
Type & supply voltage |
Totally enclosed fan-cooling outdoor type,
3-phase, 200V(50Hz/60Hz)/220V(60Hz) |
| Power/No. of poles |
0.2kW/2P |
0.75kW/2P |
0.75kW/4P |
1.5kW/4P |
| Weight (kg) |
26 |
86 |
109 |
130 |
|
|
|