| PZi Series |
|
 |
|
|
Popular PZ Series with
Intelligent Brain Now Mounted!!
When the next input signal is entered to a PZi pump during the operation in the multiplication mode, the number of pumping action after operation will be added (max. 9999 times). |
|
 |
| <Applications> |
|
- Chlorine sterilization for small-scale water-supply system,food plants, buildings and swiming pools
- Injection of chemicals to boilers
- Chemical injection in the fleld of physics and chemistry plus medical cure
- Very low flow rate at a high pressure injection of various other liquids
|
|
|
|
Ο PZi Variation
Series
Function |
PZi4 |
PZi8 |
Signal
(No of ports) |
Analog Input |
1 |
| Digital |
Input |
2 |
4 |
| Output |
- |
2 |
| Power supply to Flow Checker |
- |
Ο |
| Control |
Manual |
Digital setting |
| Auto |
Analog-Input proportional control |
O |
| Pulse-Input proportional control |
O |
Count operation
(batch control) |
- |
O |
Interval operation
(timer control) |
- |
O |
| External stop-signal control |
O |
| 2-point Level Swich control *1 |
- |
Ο |
Error/
Alarm |
Memory-read error (LCD display only) |
O |
| Tank-level alarm |
w/ 1-point Level Switch
(Pump stop only) |
O |
W/ 2-point Level Switch
(LCD display/Alarm output/Pump stop) |
- |
Ο |
| Pulse-Input error |
O
(display only) |
O |
Analog-Input error
(LCD display/Alarm output/Pump stop) |
O
(display only) |
Ο |
Lower discharge-volume alarm *2
(LCD display/Alarem output/Pump stop) |
O
(display only) |
Ο |
| Easy calibration function |
- |
| Momentary discharge-volume display function *2 |
- |
O |
| LCD display |
1-row |
1-row
(w/ backlight) |
*1 When 2-point Level Switch is used
*2 When Flow Checker is used
Ο Secifications: PZi4/PZi/ (S-size w/Relief Valve)
Model Specification |
30R |
60R |
100R |
| VTCE |
VTCF |
FTCE |
FTCF |
FTCT |
VTCE
for injection
of
boiler chemicals |
VTCE |
VTCF |
FTCE |
FTCF |
FTCT |
VTCE |
VTCF |
FTCE |
FTCF |
FTCT |
| Max. discharge volume *1 |
mL/min |
30 |
28 |
60 |
100 |
| L/h |
1.8 |
1.68 |
3.6 |
6.0 |
| Max. discharge pressure *1 |
MPa |
0.7 *2 |
1.5 |
0.7 *2 |
0.4 |
| Stroke speed |
1 to 300 strokes/min (digital setting) |
| Stroke length |
0.5 to 1.0 mm (adjustable by manual dial) |
Connection
(hose/tube:
I.D × O.D) |
Discharge side |
4 × 9
(PVC braided hose)
6 × 8
(PE)
1/4 × 3/8
(PE) |
6 × 8
(PE)
1/4 × 3/8
(PE) |
6 × 8
(FEP)
1/4 × 3/8
(FEP) |
4 × 6
(nylon tube) |
6 × 11
(PVC braided hose)
6 × 8
(PE)
1/4 × 3/8
(PE) |
6 × 8
(PE)
1/4 × 3/8
(PE) |
6 × 8
(FEP)
1/4 × 3/8
(FEP) |
6 × 11
(PVC braided hose)
6 × 8
(PE)
1/4 × 3/8
(PE) |
6 × 8
(PE)
1/4 × 3/8
(PE) |
6 × 8
(FEP)
1/4 × 3/8
(FEP) |
| Suction side |
4 ×9
(PVC braided hose) |
| Relief Valve/Air Release |
4 × 6
(soft PVC hose) |
| Max. allowable viscosity |
50 mPa•s |
| Allowable temperature |
Ambient temperature: 0 to 40 ºC / Transferring liquid: 0 to 40 ºC (no freezing allowed) |
| Environmental protection |
IEC standard: IP65 or equivalent (water- and dust-proof) |
| Signal |
Analog-Input |
| PZi4 : |
1 port : Analog signal (4 to 20 mA DC, input resistance : approx. 110Ω) *4 |
| PZi8 : |
1 port : Analog signal (4 to 20 mA DC, 0 to 20 mA, input resistance approx. 110Ω) *4 |
|
| Digital *3 |
Input |
| PZi4 : |
1 port :
1 port : |
High-speed pulse signal (no-voltage contact or open collector, input resistance: approx. 2kΩ, max. number of pulses: 7500 pulse/min, min, pulse width: 4 msec
(ON time) *4
Pump stop signal (no-voltage contact or open collector, input resistance: approx. 2kΩ, min. pulse width: 50 msec (ON time)) |
| PZi8 : |
2 ports :
2 ports : |
High-speed pulse signal (no-voltage contact or open collector, input resistance: approx. 2kΩ, max. number of pulses: 7500 pulse/min, min, pulse width: 4 msec
(ON time))) *4
Low-speed pulse signal (no-voltage contact or open collector, input resistance: approx. 2kΩ, min. pulse width: 50 msec (ON time)) |
| |
|
Signal assignments :
(4 selectable) |
Unassigned, Pulse signal, Stop signal, Reset/Restart signal, Alarm rest signal, Flow Checker signal (only when Flow Checker is used), Level Switch signal (only when Level Switch is used) |
|
| Output |
| PZi8 : |
only : 2 port : |
pulse signal (3 mA DC, 25 V or less) |
| |
|
Signal assignments :
(2 selectable) |
Unassigned, Solenoid-operation sync pulse signal, In-opetation signal, Operation and signal, Lamp alarm signal, Low tank-level alarm signal (only when 2-point Level Switch is used), Pulse-Input error signal, Analog-Input error signal, Lower discharge-volume alarm signal (only when Flow Cheker is used) |
|
| Power supply to Flow Checker *4 |
PZi8 only |
| Operation mode |
Manual |
Digital settings: 3 patterns [stroke speed (1 to 300 strokes/min, in 1 stroke/min increments), discharge volume (in 0.1 mL/min increments), percentage (1 to 100%, in 1% increments)] |
| Auto |
Analog-Input proportional control *5 |
Control possible by Proportional Band (PB/variable range: ±1 to ±999%) setting / Shift (S/variable range: 0 to ±100%) setting |
| Pulse-Input proportional control *5 |
Control possible by Frequency-division (1/1 to 1/9999) setting / Multiplication (1 to 9999) setting |
Count operation
(batch control) |
PZi8 only : 1 to 9999 strokes (×1, ×10, ×100, ×1000) |
Interval operation
(timer contror) |
PZi8 only : ON time : 1 to 9999 min/OFF time : 1 to 9999 min |
| External stop input control |
"STP" flashing display, pump stopped |
| 2-point Level Switch Control *6 |
PZi8 only : [Low tank-level alarm] "E-02" displayed and alarm output / [Lower tank-level alarm] "STP" flashing display and pump stopped |
| Power supply |
Rated voltage |
AC100 to 240V (±10%) |
| No.of phases/Frequency |
1-phase / 50 or 60 Hz |
| Maximum current |
2.2A |
| Power consumption |
Max.:220VA/Ave.:16W |
| Weight |
1.9kg |
2.0kg |
1.9kg |
1.9kg |
Note:
- Conditions: Clean water, room temperature
- Though the max. discharge pressure of the 30R models is 1.0 MPa, the Relief Valve operates when 0.7 MPa is exceeded. In applications requiring a discharge pressure of 0.7 MPa or more, ask for a model w/out the Relief Valve, and install a separate relief valve for extra safety.
- Though the max. discharte pressure of the 60R models is 0.8 MPa, the Relief Valve operates when 0.7 MPa is exceeded. In applications requiring a discharge pressure of 0.7 MPa or more, ask for a model w/out the Relief Valve, and install a separate relief valve for extra safety.
- Combined use of Analog-Input signal and high-speed pulse signal not possible.
- For a detailed explanation on signals, see "digital Signal" on Page 26.
- For details on the Flow Checker, see "Option" on the back cover.
- For details, see "Analog-Input Proportional Control" and "Pulse-Input Proportional Control" on page14.
- When 2-point Level Switch is used.
Ο Specifications:PZi4/PZi8 (S-size/L-size)
Model Specification |
30 |
60 |
100 |
300 |
500 |
| VTCE |
VTCF |
FTCE |
FTCF |
FTCT |
6TCT |
VTCE
for injection
of boiler chemicals |
VTCE |
VTCF |
FTCE |
FTCF |
FTCT |
6TCT |
VTCE |
VTCF |
FTCE |
FTCF |
FTCT |
6TCT |
VTCE |
VTCF |
FTCT |
STCT |
VTCE |
VTCF |
FTCT |
STCT |
| Max. discharge volume *1 |
mL/min |
30 |
27 |
28 |
60 |
55 |
100 |
95 |
360 |
330 |
540 |
510 |
| L/h |
1.8 |
1.6 |
1.68 |
3.6 |
3.3 |
6.0 |
5.7 |
21.6 |
19.8 |
32.4 |
30.6 |
| Max. discharge pressure *1 |
MPa |
1.0 |
0.5 |
1.5 |
0.8 |
0.5 |
0.4 |
0.3 |
0.2 |
| Stroke speed |
1 to 300 strokes/min (digital setting) |
| Stroke length |
Fixed at 1.0 mm |
0.3 to 1.5 mm (manual dial) |
Connection
(hose/tube:
I.D × O.D) |
Discharge side |
4 × 9
(PVC braided hose)
6 × 8
(PE)
1/4 × 3/8
(PE) |
6 × 8
(PE)
1/4 × 3/8
(PE) |
6 × 8
(FEP)
1/4 × 3/8
(FEP) |
6 × 8
(PTFE) |
4 × 6
(nylon tube) |
6 × 11
(PVC braided hose)
6 × 8
(PE)
1/4 × 3/8
(PE) |
6 × 8
(PE)
1/4 × 3/8
(PE) |
6 × 8
(FEP)
1/4 × 3/8
(FEP) |
6 × 8
(PTFE) |
6 × 11
(PVC braided hose)
6 × 8
(PE)
1/4 × 3/8
(PE) |
6 × 8
(PE)
1/4 × 3/8
(PE) |
6 × 8
(FEP)
1/4 × 3/8
(FEP) |
6 × 8
(PTFE) |
12 × 18
(PVC braided hose)
9 × 12
(PE)
3/8 × 1/2
(PE) |
12 × 15
(PTFE) |
12 × 18
(PVC braided hose)
9 × 12
(PE)
3/8 × 1/2
(PE) |
12 × 15
(PTFE) |
| Suction side |
4 × 9
(PVC braided hose) |
| Air Release |
4 × 6 (soft PVC hose) |
- |
| Max. allowable viscosity |
50 mPa•s |
| Allowable temperature |
Ambient temperature: 0 to 40 ºC / Transferring liquid; 0 to 40 ºC (no freezing allowed) |
| Environmental protection |
IEC standard; IP65 or equivalent (water- and dust-proof) |
| Signal |
Analog-Input |
| PZi4 : |
1 port : Analog signal (4 to 20 mA DC, input resistance : approx. 110Ω) *2 |
| PZi8 : |
1 port : Analog signal (4 to 20 mA DC, 0 to 20 mA, input resistance approx. 110Ω) *2 |
|
| Digital *3 |
Input |
| PZi4 : |
1 port :
1 port : |
High-speed pulse signal (no-voltage contact or open collector, input resistance: approx. 2kΩ, max. number of pulses: 7500 pulse/min, min, pulse width: 4 msec
(ON time)) *2
Pump stop signal (no-voltage contact or open collector, input resistance: approx. 2kΩ, min. pulse width: 50 msec (ON time)) |
| PZi8 : |
2 ports :
2 ports : |
High-speed pulse signal (no-voltage contact or open collector, input resistance: approx. 2kΩ, max. number of pulses: 7500 pulse/min, min, pulse width: 4 msec
(ON time)) *2
Low-speed pulse signal (no-voltage contact or open collector, input resistance: approx. 2kΩ, min. pulse width: 50 msec (ON time)) |
| |
|
Signal assignments :
(4 selectable) |
Unassigned, Pulse signal, Stop signal, Reset/Restart signal, Alarm rest signal, Flow Checker signal (only when Flow Checker is used), Level Switch signal (only when Level Switch is used) |
|
| Output |
| PZi8 : |
only : 2 port : |
Pulse signal (3 mA DC, 25 V or less) |
| |
|
Signal assignments :
(2 selectable) |
Unassigned, Solenoid-operation sync pulse signal, In-opetation signal, Operation and signal, Lamp alarm signal, Low tank-level alarm signal (only when 2-point Level Switch is used), Pulse-Input error signal, Analog-Input error signal, Lower discharge-volume alarm signal (only when Flow Cheker is used) |
|
| Power supply to Flow Checker *6 |
PZi8 only |
| Operation mode |
Manual |
Digital settings: 3 patterns [stroke speed (1 to 300 strokes/min, in 1 stroke/min increments), discharge volume (in 0.1 mL/min increments), percentage (1 to 100%, in 1% increments)] |
| Auto |
Analog-Input proportional control *7 |
Control possible by Proportional Band (PB/variable range: ±1 to ±999%) setting / Shift (S/variable range: 0 to ±100%) setting |
| Pulse-Input proportional control *7 |
Control possible by Frequency-division (1/1 to 1/9999) setting / Multiplication (1 to 9999) setting |
Count operation
(batch control) |
PZi8 only : 1 to 9999 strokes (×1, ×10, ×100, ×1000) |
Interval operation
(timer contror) |
PZi8 only : ON time : 1 to 9999 min/OFF time : 1 to 9999 min |
| External stop input control |
"STP" flashing display, pump stopped |
| 2-point Level Switch Control *8 |
PZi8 only : [Low tank-level alarm] "E-02" displayed and alarm output / [Lower tank-level alarm] "STP" flashing display and pump stopped |
| Power supply |
Rated voltage |
AC100 to 240V (±10%) |
| No.of phases/Frequency |
1-phase / 50 or 60 Hz |
| Maximum current |
2.2A |
| Power consumption |
Max.:220VA/Ave.:16W |
| Weight |
1.9kg |
2.0kg |
1.9kg |
1.9kg |
2.0kg |
1.9kg |
2.0kg |
4.0kg |
4.2kg |
6.0kg |
4.0kg |
4.2kg |
6.0kg |
Note:
- Conditions: Clean water, room temperature
- Combined use of analog input signal and high-speed pulse signal not possible.
- For a detailed explanation on signals, see "digital Signal" on Page 26.
- For details on the Flow Checker, see "Option" on the back cover.
- For details, see "Analog-Input Proportional Control" and "Pulse-Input Proportional Control" on page 14.
- When 2-point Level Switch is used.
Ο Liquid-end Material
Model Specification |
VTCE |
VTCF |
FTCE |
FTCF |
FTCT |
VTCE
(for injection of boiler chemicals) |
6TCT
(S-size) |
STCT
(L-size) |
| Pump head |
PVC |
PVDF |
PVC |
SUS316 |
SUS304 |
| Diaphragm |
PTFE |
| Check ball |
Ceramic |
| O-ring |
EPDM |
Fluoro-rubber |
EPDM |
Fluoro-rubber |
Special fluoro-rubber Pafulo®* |
EPDM |
PTFE |
PTFE |
| Valve seat |
EPDM |
Special fluoro-rubber |
EPDM |
Special fluoro-rubber |
PTFE |
EPDM |
- |
- |
| Joint |
PVC |
PVDF |
PVC |
SUS316 |
SUS304 |
| Ball stopper |
PVC |
PVDF |
PTFE (valve stopper) |
PVC |
PTFE (valve stopper) |
* PTFE for L-size(300/500)
Ο Model Code * Not all model combinations are possible. When selecting the pump model, first check "Specification" and "Liquid-end Material".
| PZi8 |
- |
30R |
- |
VTCE |
- |
4x9PVC |
- |
W |
- |
S |
- |
JPL |
| [1] |
|
[2] |
|
[3] |
|
[4] |
|
[5] |
|
[6] |
|
[7] |
| [1] |
Series name |
| |
|
PZi4
PZi8
|
: Analog / Digital-Input
: Analog / Digital-Input & Digital-Output |
| [2] |
Model (discharge volume standard) [for injection of general chemicals] |
| |
|
30R
60R
100R
30
60
100
300
500 |
: 30mL/min (w/ Relief Valve)
: 60mL/min (w/ Relief Valve)
:100mL/min (w/ Relief Valve)
: 30mL/min
: 60mL/min
:100mL/min
:300mL/min
:500mL/min |
| |
|
[for injection of boiler chemicals] |
| |
|
30R
30 |
: 30mL/min (w/ Relief Valve)
: 30mL/min |
| [3] |
Liquid-end material |
|
|
VTCE
VTCF
FTCE
FTCF
FTCT
6TCT
STCT
VTCE |
|
| [4] |
Hose standard (size/material) |
| |
|
4 × 9
6 × 11
12 × 18
6 × 8
9 × 12
1/4 × 3/8
3/8 × 1/2
12 × 15
4 × 6
|
PVC
PVC
PVC
PE/FEP/PTFE
PE
PE/FEP
PE
PTFE
PA |
| [5] |
Joint specification |
|
|
W
BW |
: Standard
: Bolier |
| [6] |
Applicable standard |
|
|
S
CE |
: Standard
: CE marking-compatilble |
| [7] |
Power plug |
|
|
EUP
ULP
AUP
UKP
JPL
NON |
: Euro plug
: UL plug
: Australia plug
: UK plug
: Japan lead wire
: No Cable * |
* L-size only (300/500) |
Ο Analog signal input
| |
|
[PZi4][PZi8] DC4 (0) to 20mA input |
| (1) |
Proportional band function |
 |
| |
(A) |
Pump can operate at 100% even if
the input signal is not 100% (20mA). |
| |
(B) |
Pump does not operate at full capacity
even if the input signal is 100% (20mA). |
| (2) |
Shift function |
 |
| |
(A) |
Pump discharges the minimum amount
even if the input signal is 0 (4mA). |
| |
(B) |
Pump does not start injection
until the input exceeds a certain value. |
Ο Pulse signal input
| (1) |
Frequency-division (1/1 to 1/9999 adjustable) |
[PZi4][PZi8] |
| |
 |
| (2) |
Multiplication (1 to 9999 adjustable) |
| |
 |
Ο Stop-signal input
| |
[PZi4][PZi8] |
|
ex.Level switch control
When the tank is empty:
- The pump stops [PZi4]
- The pump stops [PZi8]
- The alarm indication works.
- Alarm Signal is outputted.
|
 |
Ο Pulse signal input
| (1) |
Counter (Metering batch injection) |
[PZi8] |
| |
Pump operates up to max.9999 × 1000 times by the start(switch)signal.
Multiplication setting.(Such as × 1, × 10, × 100 and × 1000.)is available.
Type 31 discharges up to max. 0.99 × 1000. L by one signal. (Indication counts down.) |
| (2) |
Interval function |
|
| |
ON time and OFF interval can be freely set
from 1 to 9999 min. respectively.
(Operation repeats this setting.) |
 |
|
|
|