| Double-diaphragm (WA model) |
|

SYWA1-12 model |
|
|
Two diaphragms used for improved durability and corrosion resistance
A PTFE corrugated diaphragm is used on the liquid-end side to further improve durability. This makes this model ideal for use in fields such as production processes and water treatment where durability and corrosion resistance are required. A head with relief valve can also be attached. |
|
 |
This highly economical and substantial small-capacity series is ideal for extensive applications requiring high-precision and durability.
This compact metering pump comes with five types of pump heads as a quick response to differing site operating conditions and pump applications. Available are models that reliably answer an extensive range of needs including injection of trace amounts, high-pressure injection, and metered injection of high-viscosity liquids or liquids containing slurry. Moreover, multiple-series pump models and pulseless models further extend the scope of application of this series.
| <Features> |
|
- Rigid oil-bath type drive
- Available in both vertical and horizontal models for selection according to conditions of use and installation
- Duplex, triplex, and up to six in-series pumps can be manufactured. (also connectable to R series)
- Liquid-end materials have been specially selected to meet all kinds of liquid injection needs.
|
|
|
 |
(1) Discharge-side upper joint
(2) Discharge-side lower joint
(3) Suction-side joint
(4) Check ball
(5) Valve stopper
(6) Pump head
(7) Front diaphragm
(8) Buffering liquid (glycerin)
(9) Drive diaphragm
(10)Plug
(11)O-ring |
|
PTFE corrugated diaphragm  |
Ο Performance Specifications
| Model |
Max. discharge volume
(ml/min) |
Max. discharge pressure
(MPa) |
Strokes per minute (spm) |
Motor specifications
(standard)
50Hz/60Hz |
| 50Hz |
60Hz |
50Hz |
60Hz |
SXDA1
SXWA1 |
-31 |
30 |
36 |
1.0 |
53 |
63 |
Totally enclosed self-cooled
outdoor type
3-phase 200 V |
0.1kW 4P |
| -61 |
50 |
60 |
| -12 |
100 |
120 |
105 |
126 |
| -22 |
200 |
240 |
| -32 |
300 |
360 |
| -62 |
600 |
720 |
| -82 |
830 |
1000 |
Totally enclosed fan-cooled
outdoor type
3-phase 200 V |
0.2kW4P |
| -13 |
1000 |
1200 |
0.5 |
| -23 |
1500 |
1800 |
| -33 |
2500 |
3000 |
0.3 |
| -43 |
3300 |
4000 |
* The SXWA1-31 model is not available.
| Model |
Max. discharge volume
(ml/min) |
Max. discharge pressure
(MPa) |
Strokes per minute (spm) |
Motor specifications
(standard)
50Hz/60Hz |
| 50Hz |
60Hz |
50Hz |
60Hz |
SYDA1
SYWA1 |
-31 |
30 |
36 |
1.0 |
33 |
40 |
Totally enclosed fan-cooled
outdoor type
3-phase 200 V |
0.2kW 4P |
| -61 |
60 |
72 |
63 |
75 |
| -12 |
100 |
120 |
105 |
126 |
| -32 |
300 |
360 |
| -62 |
600 |
720 |
| -82 |
830 |
1000 |
| -13 |
1000 |
1200 |
0.5 |
| -23 |
1500 |
1800 |
| -43 |
3300 |
4000 |
0.3 |
* The maximum discharge volume (at 50/60 Hz) for an SXDA/SYDA1-43 model PTFE diaphragm model (VTC, VTS or STS) is 3000/3600 ml/min and the maximum discharge pressure 0.25 MPa.
Ο Standard Liquid-end Materials
Double-diaphragm type
Part name
Liquid-end type |
Pump head |
Front diaphragm |
Check ball |
Joint |
O-ring |
| VTC |
PVC |
PTFE |
Ceramic |
PVC |
Fluoro rubber |
| VTS |
PVC |
PTFE |
SUS304 |
PVC |
Fluoro rubber |
| STS |
SUS304 |
PTFE |
SUS304 |
SUS304 |
PTFE |
| FTC |
PVdF |
PTFE |
Ceramic |
PVdF |
PTFE |
 |
- Do not use outside the temperature range below as this may result in failure:
| |
Ambient temperature: 0 to 40ºC |
| |
Requirement for liquid being handled: |
| |
|
Liquid temperature: |
PVC type: 0 to 40ºC
SUS, PVDF type: 0 to 80ºC
(no freezing allowed) |
| |
|
Viscosity: |
50 MPa•s or less |
| |
|
The viscosity for high-viscosity joints is 50 to 2000 MPa•s.
However, the viscosity of high-viscosity joints on the SX(Y)DA/WA-13 to 43 types is 50 to 1000 MPa•s |
| |
Max. discharge pressure: |
| |
|
See Performance Specifications. |
| |
|
The maximum discharge pressure in the case of PTFE hose connections (STS/FTC models) is 0.5 MPa.
The maximum discharge pressure in the case of PTFE diaphragms (VTC/VTS/STS models) on the SXDA/SYDA1-43 type is 0.25 MPa. |
- This pump is not intended for pumping slurry. Please contact TACMINA if the liquid to be pumped contains slurry.
|
|